Heat Exchangers and Condensers: Operation, Maintenance and Troubleshooting
المبادلات الحرارية والمكثفات: التشغيل والصيانة وحل المشكلات
- Next date
- 1–5 March 2027Muscat
- Fees from
- £2,950per delegate
- Formats
- Classroom · Online4 sessions
- Duration
- 5 daysCertificate
Overview
Heat exchangers and condensers are found in every refinery, gas plant, petrochemical complex and power station, where they recover heat, cool products, condense vapours and control process temperatures. Their performance has a direct effect on energy consumption, throughput and product quality. Fouling, corrosion, tube leaks, vibration, poor venting and incorrect operation reduce heat transfer, cause unplanned shutdowns and can lead to hazardous leaks between process streams. Engineers and technicians who understand exchanger design and behaviour can operate, clean, inspect and repair them more effectively and at lower cost.
This course provides a practical understanding of the operation, maintenance and troubleshooting of heat exchangers and condensers. Participants learn heat transfer principles, the main exchanger types including shell and tube, plate, air-cooled and double pipe exchangers, and their design features and TEMA classifications. The course covers performance monitoring, fouling mechanisms and mitigation, cleaning methods, condensers and vacuum systems, and air cooler operation. It also explains corrosion and tube failures, tube vibration, inspection and testing methods, tube plugging and retubing, bundle handling, hydrotesting, gasket and bolting practices, and the troubleshooting of common performance and mechanical problems.
Objectives
- Apply heat transfer principles to exchanger and condenser performance
- Describe shell and tube, plate, air-cooled and double pipe exchangers
- Monitor exchanger performance and quantify the effects of fouling
- Select fouling mitigation and cleaning methods for different services
- Operate condensers, vacuum systems and air coolers effectively
- Inspect, test and repair tube bundles, tubes and exchanger shells
- Troubleshoot common performance and mechanical problems in exchangers
Who should attend
Process, mechanical and maintenance engineers, inspectors, operators, maintenance technicians and supervisors working with heat transfer equipment.
Training methodology
The course combines explanation of heat transfer and exchanger design with real data sheets, operating data, inspection reports and photographs of fouled and failed equipment. Participants calculate heat duties and overall heat transfer coefficients, track fouling resistance over time, select cleaning methods, interpret eddy current inspection results and plan tube plugging limits. Bundle pulling, cleaning and hydrotest procedures are explained step by step. Troubleshooting cases from refinery preheat trains, overhead condensers and air coolers are solved in small groups. Each day ends with a short quiz and discussion.
Programme outline
Day1Heat Transfer and Exchanger Types
- Roles of heat exchangers and condensers in process plants and their effect on energy use
- Conduction, convection and the overall heat transfer coefficient explained with plant examples
- Log mean temperature difference, heat duty and the basic heat exchanger equations
- Shell and tube exchangers and the meaning of TEMA front, shell and rear types
- Plate, plate-fin, double pipe and spiral exchangers and their typical applications
- Air-cooled heat exchangers, their fans, tube bundles and the main control methods used
- Practical exercise: calculating heat duty and overall heat transfer coefficient from plant data
Day2Performance Monitoring and Fouling
- Monitoring exchanger performance using measured temperatures, flows and pressure drops across both sides
- Fouling mechanisms such as scaling, particulate, corrosion, biological and chemical fouling
- Calculating fouling resistance from plant data and tracking its growth over time
- The cost of fouling in energy, throughput and cleaning and its effect on margins
- Fouling mitigation through velocity, temperature control, antifoulants and design changes
- Preheat train monitoring and optimisation of cleaning schedules in refineries
- Practical exercise: tracking fouling resistance and planning the best time to clean
Day3Condensers, Vacuum Systems and Air Coolers
- Condensation principles and the effect of non-condensable gases on condenser performance
- Surface condensers, vacuum systems, ejectors and their operation and troubleshooting
- Overhead condensers on distillation columns and the control of column pressure
- Air cooler operation, fan control, louvres and the effect of ambient temperature
- Freezing, hydrate and wax risks in air coolers and condensers in cold conditions
- Venting, draining and the prevention of water hammer in steam-heated exchangers
- Practical exercise: diagnosing poor condenser performance from real plant operating data
Day4Mechanical Problems, Inspection and Testing
- Tube corrosion, erosion, pitting and cracking and the influence of materials and water quality
- Flow-induced tube vibration and the damage it causes at baffles and tube sheets
- Inspection methods: eddy current, IRIS, remote field testing and visual inspection
- Tube sheet, channel and shell inspection and the detection of hidden damage
- Leak testing, hydrotesting and the reliable identification of leaking tubes in bundles
- Tube plugging limits and decisions on retubing or replacing bundles
- Practical exercise: interpreting eddy current inspection results and setting plugging limits
Day5Maintenance, Cleaning and Troubleshooting
- Mechanical and chemical cleaning methods, including hydroblasting and online cleaning
- Safe bundle pulling, lifting, handling, transport and reinstallation procedures on site
- Gasket selection, bolting and controlled joint tightening for exchanger channel and shell closures
- Commissioning exchangers after maintenance and avoiding thermal shock during start-up
- Troubleshooting low heat transfer, high pressure drop, leaks and vibration problems
- Group exercise: troubleshooting a refinery preheat train with falling furnace inlet temperature
- Final assessment and discussion of exchanger issues at participants' own plants
Dates and fees
Fees are in GBP. per delegate.
Certificate
Every delegate who attends the full programme receives a Harfard Technology certificate of completion stating the course title, duration, dates and venue.
Frequently asked questions
Will I receive a certificate?
What is the difference between classroom and online?
Can you run this course for our company?
How do I register?
Related courses
Maintenance, Reliability & Asset IntegrityReliability-Centred Maintenance
15–19 March 2027 · Geneva +4 dates
Maintenance, Reliability & Asset IntegrityRotating Equipment: Pumps & Compressors
21–25 June 2027 · Barcelona +3 dates
Maintenance, Reliability & Asset Integrity