Generators and Excitation Systems
المولدات وأنظمة الإثارة
- Next date
- 8–12 February 2027Online
- Fees from
- £2,950per delegate
- Formats
- Online · Classroom4 sessions
- Duration
- 5 daysCertificate
Overview
Generators are at the heart of on-site power generation in oil, gas, refining and petrochemical facilities, where gas turbine, steam turbine and diesel driven sets supply power to process plants that often operate in island mode or in parallel with weak grids. The performance of a generator and its excitation system directly affects voltage stability, reactive power sharing, fault ride-through and the ability of the plant to survive disturbances. Generator failures are costly and slow to repair, so engineers and technicians need a sound understanding of how these machines work, how they are protected and how they should be maintained.
This course provides a practical understanding of synchronous generators and their excitation systems. Participants learn generator construction and operating principles, ratings and capability curves, cooling systems, and the behaviour of generators in island and parallel operation. The course covers excitation system types, automatic voltage regulators, power system stabilisers, reactive power control and limiters, together with synchronising, load sharing and governor interaction. It also explains generator protection schemes, condition monitoring techniques such as partial discharge and insulation testing, commissioning and routine testing, maintenance strategies and the diagnosis of common generator and excitation faults.
Objectives
- Explain synchronous generator construction, operation and ratings
- Interpret generator capability curves and operating limits
- Describe excitation system types, AVRs and limiters
- Explain synchronising, load sharing and island mode operation
- Describe generator protection schemes and their settings philosophy
- Apply condition monitoring and testing techniques to generators
- Diagnose common generator and excitation system faults
Who should attend
Electrical engineers, power plant engineers and technicians, protection engineers and maintenance supervisors responsible for generators.
Training methodology
The course combines clear technical explanation with worked examples, simulations and case studies from industrial power plants. Participants interpret capability curves, analyse AVR and governor responses, review synchronising procedures and protection settings, and interpret insulation and partial discharge test results. Case studies examine generator trips, loss of excitation events and winding failures. Group exercises focus on operating generators safely in island mode and in parallel with the grid. Each day ends with a short quiz and discussion of generator issues at participants' plants.
Programme outline
Day1Generator Fundamentals
- Role of on-site generation in oil, gas and petrochemical facilities and typical prime movers
- Synchronous generator construction including stator, rotor, windings, bearings and the main terminal box
- Operating principles, frequency, speed, poles and the generation of three-phase voltage
- Generator ratings, power factor and the relationship between real and reactive power
- Generator capability curves and the thermal and stability limits they represent
- Cooling systems using air, hydrogen and water and their monitoring requirements
- Practical exercise: interpreting a capability curve and plotting several operating points
Day2Excitation Systems and Voltage Control
- Purpose of excitation and the effect of field current on voltage and reactive power
- Excitation system types including brushless, static and rotating DC exciters
- Automatic voltage regulators, control modes and reactive power and power factor control
- Over-excitation, under-excitation and volts per hertz limiters and why they are needed
- Power system stabilisers and their role in damping oscillations after disturbances
- Excitation system testing and the tuning of AVR response for stable operation
- Practical exercise: analysing AVR step response records and identifying tuning problems
Day3Parallel Operation and Island Mode
- Synchronising conditions, synchroscopes and automatic synchronisers used for safe paralleling of generators
- Load sharing of real power through governors and droop or isochronous control
- Reactive power sharing between generators and voltage droop compensation methods
- Island mode operation, frequency control and load shedding in weak power systems
- Behaviour of generators during faults, motor starting and large load changes
- Interaction between generators, the grid connection and plant power management systems
- Practical exercise: reviewing a synchronising procedure and load sharing settings
Day4Generator Protection
- Generator protection philosophy and the main faults that protection must detect
- Stator earth fault, differential and overcurrent protection schemes for generators
- Loss of excitation, reverse power, negative sequence and over and under frequency protection
- Rotor earth fault protection and the risks of a second rotor earth fault
- Protection settings, coordination with the network and trip logic for generator breakers
- Lessons from generator trips and protection mal-operations in industrial plants
- Practical exercise: reviewing a generator protection settings table against fault scenarios
Day5Condition Monitoring, Testing and Maintenance
- Insulation resistance, polarisation index and other offline insulation tests for windings
- Partial discharge monitoring and its value in detecting insulation deterioration early
- Vibration, temperature and bearing monitoring for generators and their exciters
- Inspection and maintenance of stators, rotors, slip rings, brushes and cooling systems
- Diagnosing common faults such as overheating, unbalance, excitation failures and insulation breakdown
- Group exercise: developing a condition monitoring and maintenance plan for a generator
- Final assessment and discussion of generator reliability at participants' plants
Dates and fees
Fees are in GBP. per delegate.
Certificate
Every delegate who attends the full programme receives a Harfard Technology certificate of completion stating the course title, duration, dates and venue.
Frequently asked questions
Will I receive a certificate?
What is the difference between classroom and online?
Can you run this course for our company?
How do I register?
Related courses
Electrical, Instrumentation & ControlSafety Instrumented Systems (IEC 61511)
4–8 January 2027 · Madrid +4 dates
Electrical, Instrumentation & ControlProcess Control & Instrumentation
28 December 2026 – 1 January 2027 · Berlin +2 dates
Electrical, Instrumentation & Control