Electrical Power Systems for Mission-Critical Facilities

أنظمة القوى الكهربائية للمنشآت الحرجة

Next date
18–22 January 2027Online
Fees from
⁦£2,950⁩per delegate
Formats
Online · Classroom4 sessions
Duration
5 daysCertificate

Overview

Data centers depend on electrical systems that must deliver clean, continuous power to IT equipment even when the utility fails, equipment breaks or maintenance is under way. From medium voltage incomers and transformers to generators, uninterruptible power supplies, switchboards, busways and rack power distribution, every part of the chain must be designed for resilience and safety. As AI deployments push power densities and facility capacities to new levels, electrical design decisions now have an even greater effect on cost, speed of delivery and the ability to expand without disruption.

This course provides an engineering view of electrical power systems for mission-critical facilities. Participants learn how power flows from the utility connection to the server, how redundancy topologies are built, and how to size the main components of the electrical infrastructure. The course covers medium and low voltage distribution, transformers, standby generation, UPS technologies and energy storage, static transfer switches, busway and rack power distribution, grounding, power quality and protection coordination. It also explains arc flash safety, maintenance strategies, monitoring with electrical power management systems, and the electrical implications of high-density AI loads and fast load changes.

Objectives

  • Trace the power path from utility connection to the server power supply
  • Compare redundancy topologies and their effect on availability and cost
  • Size transformers, generators, UPS systems and distribution equipment
  • Select UPS technologies and energy storage for mission-critical loads
  • Apply grounding, power quality and protection coordination principles
  • Plan safe operation and maintenance, including arc flash risk management
  • Assess the electrical impact of high-density AI loads and fast load changes

Who should attend

Electrical engineers, power system designers, consultants, commissioning engineers and critical facility electrical leads.

Training methodology

The course combines engineering principles with single line diagram reviews, sizing calculations and failure scenario analysis. Participants trace power paths on sample diagrams, compare redundancy topologies, size generators and UPS systems for a defined facility, and examine protection coordination studies and arc flash labels. Failure mode exercises test how each topology behaves during utility loss, component failure and maintenance. Case studies of outages in operating data centers show how design and operational decisions combine. Each day ends with a short design review and quiz.

Programme outline

Day1Power Path and Redundancy Concepts
  • How power flows from the utility grid through the facility to IT equipment
  • Availability concepts, single points of failure and concurrent maintainability in electrical design
  • Common redundancy topologies including N+1, 2N, distributed and block redundant designs
  • Reading data center single line diagrams and identifying critical power paths
  • Capacity planning, diversity factors and load growth assumptions for electrical design
  • Industry tier and rating frameworks and how designers should use them
  • Exercise: tracing failure scenarios through two alternative single line diagrams
Day2Medium Voltage, Transformers and Generation
  • Utility connections, medium voltage switchgear and ring main arrangements for large sites
  • Transformer sizing, impedance, losses and cooling for data center duty
  • Standby generator sizing, load acceptance, ratings and paralleling arrangements for critical loads
  • Fuel systems, storage duration and fuel quality management for generators
  • Automatic transfer schemes and the sequence of events during a utility outage
  • On-site generation and grid support options for large AI campuses
  • Exercise: sizing generators and transformers for a defined critical load
Day3UPS Systems and Energy Storage
  • Double conversion, line-interactive and other UPS technologies compared for critical loads
  • Static and rotary UPS systems and their behavior during transfers and faults
  • Battery technologies including VRLA and lithium-ion and their fire safety implications
  • Runtime calculation, battery sizing and the coordination with generator start times
  • Static transfer switches, dual-corded loads and the protection of single-corded equipment
  • UPS efficiency, eco modes and their trade-offs between energy and risk
  • Exercise: sizing a UPS and battery system for a high-density data hall
Day4Distribution, Grounding and Protection
  • Low voltage switchboards, busways and power distribution units in the white space
  • Rack power distribution, three-phase supply and higher density power delivery
  • Grounding and bonding design for safety, noise control and lightning protection
  • Power quality issues including harmonics, voltage sags and transients and how to mitigate them
  • Short-circuit studies, selective coordination and the setting of protective devices
  • Arc flash studies, labeling, safe work practices and engineering mitigation
  • Exercise: reviewing a protection coordination study for a critical distribution path
Day5Operation, Monitoring and AI Load Challenges
  • Electrical power management systems, metering and alarm management for critical facilities
  • Maintenance strategies, switching procedures and method of procedure documents for live systems
  • Infrared scanning, breaker testing and battery monitoring to improve electrical reliability
  • Electrical behavior of AI clusters, including large and rapid load fluctuations
  • Lessons learned from electrical outages and human error in operating facilities
  • Team project: presenting an electrical concept design for a new AI data hall
  • Final assessment and discussion of electrical challenges in participants' facilities

Dates and fees

18–22 January 2027January 2027
OnlineOnline
Open
⁦£2,950⁩
17–21 May 2027May 2027
Kuala LumpurMalaysia
Open
⁦£4,500⁩
2–6 August 2027August 2027
Kuwait CityKuwait
Open
⁦£4,450⁩
6–10 December 2027December 2027
RiyadhSaudi Arabia
Open
⁦£4,450⁩

Fees are in GBP. per delegate.

Certificate

Every delegate who attends the full programme receives a Harfard Technology certificate of completion stating the course title, duration, dates and venue.

Frequently asked questions

Will I receive a certificate?
Yes. Every delegate who attends the full programme receives a Harfard Technology certificate of completion.
What is the difference between classroom and online?
The content and trainer are the same. Classroom sessions run in a training venue in the chosen city; online sessions are live with the trainer over the internet.
Can you run this course for our company?
Yes. We deliver the course in-house at your premises or in a city you choose, adapting examples and exercises to your facilities.
How do I register?
Choose a date and click "Register", or send your request from the contact page. Our team will contact you to confirm your seat and send payment details.